    The Steel Insulated Fire-Rated Window is designed to provide superior fire protection, thermal insulation, and durability for residential, commercial, and industrial buildings. Constructed with high-strength steel frames and insulated glass panels, it effectively resists heat, smoke, and flames while maintaining energy efficiency. Ideal for hospitals, schools, laboratories, and industrial facilities, this window ensures safety, reliability, and compliance with international fire safety standards.
  • Share:
  • Contact us Inquiry
  • WhatsApp:8613933490119

Steel Insulated Fire-Rated Window

1. Product Overview

The Steel Insulated Fire-Rated Window is specifically designed to provide enhanced safety, fire resistance, and thermal insulation in residential, commercial, and industrial buildings. By combining durable steel frames, insulated glass panels, and certified fire-resistant materials, this window ensures both protection and energy efficiency.

Key Features:

  • Fire resistance tested for various durations (30, 60, 90 minutes).

  • High-strength steel frame for durability and security.

  • Insulated glass panels to maintain thermal comfort.

  • Smoke and heat barrier for emergency scenarios.

  • Compliance with international fire safety standards.

This window is ideal for high-risk areas such as commercial kitchens, laboratories, hospitals, and industrial buildings, ensuring safety without compromising design or functionality.


2. User Guide

Proper usage of Steel Insulated Fire-Rated Windows ensures maximum safety and longevity.

2.1 Installation Guidelines

  • Verify window dimensions and wall opening for a proper fit.

  • Ensure the surrounding structure is level and structurally sound.

  • Install using certified anchors and fasteners.

  • Confirm the frame is sealed to prevent smoke or heat leakage.

2.2 Safe Operation

  • Only trained personnel should open or close the window if integrated with emergency smoke vents or fire shutters.

  • Avoid applying excessive force to insulated glass panels.

  • Keep emergency procedures visible in fire-prone areas.

2.3 Recommended Usage Areas

  • Hospitals and medical facilities.

  • Schools and public buildings.

  • Industrial workshops and laboratories.

  • Commercial kitchens and storage areas for flammable materials.

Proper adherence to these guidelines ensures the window performs effectively in fire emergencies while maintaining durability for daily use.


3. Usage Recommendations

Steel Insulated Fire-Rated Windows require specific handling and environment considerations:

  1. Avoid Direct Impact: Steel frames and glass are durable but can be damaged by strong impact.

  2. Regular Monitoring: Check seals and glazing for wear or damage to maintain fire and thermal performance.

  3. Temperature Extremes: Ensure installation does not expose the window to direct, prolonged high temperatures outside its rated limits.

  4. Integration with Safety Systems: If used with smoke detectors or automatic vents, ensure connectivity and testing are regularly performed.

Following these recommendations enhances both safety performance and product lifespan.


Steel insulated fire-rated window


4. Maintenance Frequency

To maintain fire rating and operational integrity, regular maintenance is essential:

ComponentMaintenance FrequencyRecommended Action
Steel FrameEvery 6 monthsInspect for rust, scratches, and repaint or touch up if necessary
Insulated GlassEvery 6 monthsClean with non-abrasive cleaner; check for cracks or fogging
Seals & GasketsEvery 6 monthsInspect for wear or compression; replace if compromised
Hinges & HardwareEvery 3 monthsLubricate moving parts; ensure smooth operation
Fire Shutters / VentsEvery 12 monthsFunctional testing of automatic systems

Regular maintenance ensures consistent fire and smoke protection, operational reliability, and energy efficiency.


5. Maintenance Methods

Proper care prolongs the window’s service life and maintains its fire-resistant performance.

5.1 Cleaning Methods

  • Use soft cloths or sponges with mild detergents.

  • Avoid harsh chemicals or abrasive materials to protect steel coatings and glass surfaces.

  • For glass panels, non-ammonia-based cleaners are recommended to avoid damage to seals.

5.2 Rust Prevention

  • Inspect steel frames for scratches or corrosion.

  • Apply rust-preventive coatings or repaint damaged areas.

  • Avoid prolonged exposure to moisture and water accumulation.

5.3 Seal and Gasket Care

  • Ensure rubber or silicone seals are free from dirt and debris.

  • Replace worn seals promptly to maintain thermal insulation and fire integrity.

5.4 Hardware Maintenance

  • Lubricate hinges, locks, and any mechanical opening devices periodically.

  • Test automatic fire vent or shutter mechanisms to ensure proper operation.

By adhering to these methods, the Steel Insulated Fire-Rated Window will continue to provide safety, efficiency, and durability over time.


6. Advantages

The Steel Insulated Fire-Rated Window offers multiple advantages over standard windows:

  • Fire Safety: Tested to resist flames, heat, and smoke for certified durations.

  • Durability: Steel frames resist warping, corrosion, and damage.

  • Thermal Insulation: Insulated panels improve energy efficiency in buildings.

  • Ease of Maintenance: Simple cleaning and inspection procedures.

  • Compliance: Meets international building codes and fire safety standards.

These features make it suitable for critical safety applications where both security and energy efficiency are essential.


7. Conclusion

The Steel Insulated Fire-Rated Window is an ideal solution for safe, durable, and energy-efficient building design. By following proper installation, usage, and maintenance guidelines, building managers can ensure long-lasting performance, fire safety compliance, and optimal thermal insulation.

Investing in these windows provides peace of mind, protection of assets, and a safer environment for occupants, particularly in schools, hospitals, laboratories, and industrial facilities.

ONLINE MESSAGE

Please fill in a valid email address
Captcha Can not be empty

RELATED PRODUCTS

No search results found!

This website uses cookies to ensure you get the best experience on our website.

Accept Reject